Rolling back to the previously installed version of ExOS
If you have updated the version of ExOS running on your Exinda Appliance, you can rollback to the previously installed version. Exinda Appliances have two partitions for installing ExOS updates. The current (running) ExOS version is installed on one partition and the previously installed version is on the other partition. This allows you to revert to the older ExOS version.
IMPORTANT
When rolling back to a previous ExOS version, the system configuration changes to the state it was in the last time the older version ran. If you made changes to the system configuration since upgrading from the older version, they will be lost when the Exinda appliance is rolled back.
- On your browser, open the Exinda Web UI (
https://Exinda_IPInternet protocol_address
). - Key-in the User and Password.
- Click Login.
- Click Configuration > System > Maintenance and switch to the Firmware Update tab.
- In the Current Installed Images area, click Switch Boot Partition.
- To finalize the ExOS install, reboot the appliance. The Exinda Appliance reboots, running the previous version of ExOS. For more information refer to Reboot/Shutdown.